How will you Protect aeroplanes and Ships from Lightining?

Answers were Sorted based on User's Feedback



How will you Protect aeroplanes and Ships from Lightining?..

Answer / raam

for aero planes lightning is not appplicable since not
connected with earth during travelling. for ships, through
franklin rod systems

Is This Answer Correct ?    8 Yes 1 No

How will you Protect aeroplanes and Ships from Lightining?..

Answer / ragu

THE AEROPLANE AND SHIPS HAVE SHARP EDGE ON THE TOP OF THE
BODY THIS DIVERT THE LIGHTING TO GROUND

Is This Answer Correct ?    4 Yes 4 No

How will you Protect aeroplanes and Ships from Lightining?..

Answer / amit khamesra

The outer shield of the aircraft is of Aluminium which is
light and conducting material. Being Light, it hepls
reducing weight and being conductive it accumuklated the
charges produced by lightning on the outer surface of the
aircraft. As we know, the charge remains on the surface of
the sphere and does not impact htte inner part. When
aircraft lands, the body is grounded and the charges are
grounded.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

Will a 230VAC motor run OK at 208VAC.

7 Answers  


can a generator with 15AH specified battery for starting can be connected to a battery of greater capacity?

2 Answers  


HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

0 Answers   TMB,


How grounding is different than earthings?

0 Answers  


Please give me a erda placement paper

0 Answers  






why nutral and earthing wire connect with each other in main panel board.

2 Answers  


how work the lighting arrestor?

2 Answers  


What is gross error?

0 Answers  


how we can varying the speed of dc motor ?

6 Answers  


in elevator industries , how to calculate the required KVA for the elevator (elevator spec- 40A module , motor of 13.5KW, 20A)

1 Answers   DLF, Tata Steel Limited,


what is the ranje of HT cabel and LT Cabel.

1 Answers   Sail,


why the transformer neutral earthing is to be done by copper flat only,if we use GI flat what is the disadvantage.

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)