Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the deference between Residual solvents and OVI



What is the deference between Residual solvents and OVI..

Answer / firoz ghanchi

Residual Solvents in pharmaceuticals are Organic volatile
chemicals that are used or produced in the manufacture of
drug substance or excipient or in the preparation of drug
product.
Residual solvents refer to the amount not removed during
the purification of the drug product.
Organic Volatile impurities are
1.Dichloromethane(600ppm)
2.Chloroform(60ppm)
3.Trichloroethylene(80ppm)
4.1,4-Dioxane(380ppm)
these four solvents are OVI solvents
Remaining solvents are residual solvents.

Is This Answer Correct ?    2 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

what is lod and loq

3 Answers  


HOW RRF IS CALCULATED IN HPLC

2 Answers  


Why chromic acid wash is not recommended by USP for glassware cleaning?

1 Answers   Lupin,


why holmium perchloate solution in Uv calibration

2 Answers   Alembic,


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

0 Answers   Srini Pharmaceuticals,


which pharmacopeoia mentions that caffiene is used as a standard for HPLC calibration? which other standardscan be used for the same?

1 Answers   Hetero, Mylan,


why potassium dicromate use in calibration of UV VIIBLE SPECTROCOPY ?

3 Answers  


why we are performing residue on ignition?

6 Answers  


Is it necessary to validate both assay and related substances for usp official methods for products.

6 Answers   Apotex,


WHY POTASSIUM DICROMATE USING IN UV CALIBRATION

1 Answers   Apotex, Micro Labs, Rene,


Why caffeine as a reference standard used for calibration of HPLC?

11 Answers   Gangwal Chemicals, Orchid,


What is the Baseline in HPLC.

2 Answers   Teva API,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)