Calculate the cooling duty, H required to condense and cool acetone from 100 degree Celsius to 25 degree Celsius at atmospheric pressure. The heat of vaporization for acetone at its normal boiling point is 30.2 kJ / mol. The boiling point of acetone at atmospheric pressure is 56 degree Celsius. The flowrate of acetone through the condenser is 100 mol / s = N. Value of sensible heat needed to increase the temperature of acetone in liquid form from 25 to 56 degree Celsius is 4.06 kJ / mol. Value of sensible heat needed to increase the temperature of acetone in vapor form from 56 to 100 degree Celsius is 3.82 kJ / mol. Unit of H is kJ / s.
Answer / kang chuen tat (malaysia - pen
Answer 13 : In the same state, total heat changes in heating = total heat changes in cooling for acetone. H = N ( total heat of sensible + heat of vaporization) = 100 (mol / s) [ (30.2) + (4.06 + 3.82) ] (kJ / mol) = 3808 kJ / s. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
i want pattern of ONGC Written examination
13 Answers IOCL, ONGC, Reliance,
For cement company what type of questions come in written exam?
Explain what is the method involved in analyzing powders for composition?
what is difference between urea and NPK fertiliser?
Hi, This is Naveen, plz if anybody have experience of IOCL interview, send me question.
CHEMICAL ENERGY BALANCE - EXAMPLE 11.1 : Please match the term A - E with the stated definition i - v. Terms : A. Yield. B. Selectivity. C. Relative saturation. D. Molal saturation. E. Absolute saturation. Definitions : i. (moles of desired product formed) / (moles that would have been formed if there were no side reactions and the limiting reactant has reacted completely); ii. (moles of desired product formed) / (moles of undesired product formed); iii. (relative humidity 40 % means partial pressure of water vapour equals 4 / 10 of the vapour pressure of water at the system temperature); iv. (moles of vapour) / (moles of vapour dry gas); v. (mass of vapour) / (mass of dry gas).
What are advantages using hollow shaft impeller?
Please help me send me questions for HPCL written test of Chemical Branch.I will be highly thankful to u...
how to calculat suction head in centrifugal pump?
What is critical radius of insulation?
Are there any general rules for flushing slurry lines?
In engineering economy, the future value of first year is FV = PV (1 i). For second year it is FV = PV (1 i) (1 i). For third year it is FV = PV (1 i) (1 i)(1 i) where FV = future value, PV = present value, i = interest rate per period, n = the number of compounding periods. By induction, what is the future value of $1000 for 5 years at the interest rate of 6%?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)