what is the principle of AWC (Auto weight control) in
compression machine.
Answers were Sorted based on User's Feedback
Answer / kalpesh valand
AWC is working on the principal of compaction force controller. AWC is maintain weight in refrance through Compaction force.
| Is This Answer Correct ? | 146 Yes | 7 No |
Answer / prakash gupta
AWC work on the principal of Compression force. In this first we set the machine on lower fill weight against the standard limit of the product and observe the avg. compression force. Similarly set the machine for higher fill weight and observe the avg. compression force.
Now set the target fill weight and run the machne, acquire the reference value of force at desied parameter. Now feed the value of higher and lower compression force as observed above.
| Is This Answer Correct ? | 135 Yes | 8 No |
Answer / deepak mudgal
Awc is based on comaction force control,initial we will set average weight,thats called Ref.pressure supose you will get 15 kn.then set lower and higher average weight,thats called as LEP and HEP.so ref.pressure 15 kn. HEP 19 kn.LEP 11 kn. HCP and LCP is 3-5 %.and HSP and LSP 10% more than HEP and LEp.
| Is This Answer Correct ? | 55 Yes | 6 No |
Answer / p s krishnamurthy
to maintain the uniformity indivudial and group weight of compression tablets.
| Is This Answer Correct ? | 58 Yes | 12 No |
Answer / dinesh
automatic weight control device it is important to note that changes to press settings like thickness, speed, force feeders, and pre-compression can be misinterpreted by the force monitor. Proper steps must be followed to prevent improper operation. Then acceptable tablet weight ranges are established so that off weight tablets can be automatically rejected.
| Is This Answer Correct ? | 36 Yes | 4 No |
Answer / sidesh reddy
awc define only controling the force acording on setting the parameter by observing and command from load cell to servo motor
| Is This Answer Correct ? | 16 Yes | 3 No |
Answer / satya
AWC means automatic weight controling system . It is depends on force control system.
| Is This Answer Correct ? | 10 Yes | 2 No |
Answer / kumaraswamy
AWC working up on compaction force.it is depended by hydraulic pressure. Tablet thick ness and hardness observation our settings.
| Is This Answer Correct ? | 5 Yes | 0 No |
Answer / tota bhoganna
While running the comp machine in between fill depth was changed and Peres’s the Aquire button
What happened and which parameters are effected
| Is This Answer Correct ? | 0 Yes | 0 No |
i have completed b. pharmacy .i want model papers for drug inspector examination
which is best Training Institute for Clinical Data Management,sdtm,sas ?
What are the stability zones and stability conditions?
please tell me croscarmellose sodium usp Water-soluble substances calculation and give me exmpl
what are the role of medical reperstative
i have completed my B pharmacy i am trying to attempt group exam i have no idea of which group to select,where to take coaching any body can help me pls
1 Answers Cipla, Ranbaxy, RC Reddy,
Why 3X sampling plan are implemented in process validation?
what is Alcova
What is difference between method transfer and method verification ?
If a drug possesses zwitter ionic nature then can it plays any important role in pharmacy?
3 Answers Cipla, Orion Laboratories,
HOW TO PERFORM SATURATION SOLUBILITY IN DISSOLUTION METHOD DEVELOPMENT?
how the qualification of pharma can help in banking
0 Answers Banking, Reddy Labs,