Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


how to calculate corelation coefficient in G.C Calibration?
what is the calculation part?



how to calculate corelation coefficient in G.C Calibration? what is the calculation part? ..

Answer / babasaheb gilbile

Liquid GC calibration Correlation Coefficient calculated Volume vs Response.
And GC HS calibration Correlation coefficient calculated against Cons. Vs Area ratio with internal Std.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why in hplc peaks are in positive side(it means upside) not in negative side?

3 Answers  


about analytical chemistry

0 Answers   Apotex,


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

0 Answers  


From where 16 or 5.545 is derived in theoretical plates calculation formula by USP or JP/BP/DAB and what is meaning of this coefficient and impact in calculation ?

2 Answers   Nectar Lifesciences,


what is the difference between BDS and ODS Columens and both are same or not

2 Answers   Intas, IPQA, Micro Labs, Vasava Engineering Private Limited,


Why we are injecting low load standard conc. while analysing Related Substances by HPLC?

3 Answers  


Why we check moisture,ash & AIA in product

0 Answers  


what is Fourier Transform

3 Answers   Graviti Pharmaceuticals, GVK,


in hplc chromatogram started from left to right and in uv spectrum started from left to right

0 Answers  


why does the result variation in hplc and gc with same sample ?

4 Answers   Matrix,


i set electrode to 7 buffer than i used it to check 4 buffer and 10 buffer if the results are not as expected than is it better to set the buffer again to 4 buffer or is there any other method available please let me know ...

2 Answers   Glochem,


i want to know about headspace and interview question on headspace

1 Answers   Srikem Laboratories,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)