Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


from where i get mortar pastle for glass bottle crush? it's required for testing of it?


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Analytical Chemistry Interview Questions

what is defferance between dipolemoment and polarity

1 Answers   Neuland,


what is the difference between qualitative analysis and quantitative analysis and explain them?

1 Answers   Dr Reddys,


1 why polyesterene film used for ftir calibration ? 2 why k2cr2o7 is used for control of abs in uv ? 3 why holmium oxide used for control of wavelength in uv

3 Answers  


How can we calculates the solubility of the drug in different medias by injecting in to hplc????(solubility studies)

2 Answers   Super Pharmaceuticals,


Why we have to take 42gm of sodium hydroxide instead of 40gm for preparation of 1M Sodium hydroxide as per Pharmacopia? Whether it means the formula for calculating molarity was wrong? 

5 Answers   Claris Otsuka, Ranbaxy,


hii, i'm had a sample of 1L that gone through extraction & evaporation. i used 0.5ml of methanol for reconstitution before injecting the sample to HPLC. i made a calibration curve using a standard solution but now i'm confused about how to display the concentration i got from the sample. for ex. i got 0.2ug/ml how i'm gonna explane this is for the 1L ? please help .. i'll really appreciate it thanks

1 Answers  


In performance Check of GC Why Hexadecane Peak is Considered 

0 Answers   Asian Paints, MSN Pharma,


what r the parts calibrated in gc

21 Answers   ELBS, Reddy Labs,


If vendor having more imp than monograph then how to proceed? and how to set spec?

0 Answers  


If compound Pka is 5 then which buffer you will select ?

5 Answers   Avra, GVK,


if rsd failed then what require to do?

0 Answers  


In the gas chromatography what is used carrier gas and make up gas?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)