Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How we get DST moisture 15.4-16.0%. what is the calculation
or method behind it.

Answers were Sorted based on User's Feedback



How we get DST moisture 15.4-16.0%. what is the calculation or method behind it...

Answer / manojmishra

The molecular formula of Di sodium Tartrate dihydrate is
C4H4O6Na2ยท2H2O and mwt is 230.08gm
Hence, the participation of water in this mwt is 36gm and
rest of 230.08-36= 194.08 is DST wt:
So, the theoritical %water content is calculated as under:

36 x 100/230.08= 15.64%

The tolerance in water may be between 15.4 to 16.0%.

Is This Answer Correct ?    60 Yes 5 No

How we get DST moisture 15.4-16.0%. what is the calculation or method behind it...

Answer / ramalingeswararao

atually Water moleculor weight 18.02 grams 2 molicules
present in it so 2*18.02
di sodium weight 230.07


that is 2*18.02/230.07=0.1566

Is This Answer Correct ?    38 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

how to regulate noise in hplc ?

2 Answers  


what is use of acetonitrile compare to methanol in RP-HPLC Method devlopment

7 Answers   Neuland, Orchid,


why using buffers in hplc inteed of water

5 Answers  


effect of Ph during analytical run ?

1 Answers   Lambda Therapeutic Research,


Why we are injecting low load standard conc. while analysing Related Substances by HPLC?

3 Answers  


From where require to take the RLD sample?

0 Answers  


Which Pharmacopiea follow calibration of HPLC,GC

3 Answers   Bayer, Reddy Labs,


how to develop the shorter run time for pharmacopeial methods having 100 min run time?

3 Answers   Reddy Labs,


reasons for negative peaks in chromatography

5 Answers   DRL,


why we multiply 1000 in the determination of kf factor ?

3 Answers   Stellence Pharm Science,


wen v have polr solvent then which type of column use in hplc

2 Answers  


What is the size of capillary tube used for analysing melting point?

1 Answers   Apotex,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)