Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


where will u provide construction joint on slab?

Answers were Sorted based on User's Feedback



where will u provide construction joint on slab?..

Answer / mrdraj100

especially where there is less bending moment acting or BM is
zero.

Is This Answer Correct ?    2 Yes 1 No

where will u provide construction joint on slab?..

Answer / raghvendra vikram singh

At minimum shear force .
L/3

Is This Answer Correct ?    1 Yes 0 No

where will u provide construction joint on slab?..

Answer / bilal

For a span = & > 6m

Is This Answer Correct ?    1 Yes 0 No

where will u provide construction joint on slab?..

Answer / babu lal nayak

minimum 30" far from nearest beam....

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Civil Engineering Interview Questions

does the compressive strength of brick be more then 3.5 n/mm2 or 5 n/mm2?

3 Answers   L&T, Modi Builders,


What is the ratio of cement,sand,aggregate of mix m25

9 Answers  


how much lap we should provide in columns for Fe-500?

8 Answers  


indiploma civil engineering student r studied is456-1978. but in practicial we r using 2000 version i think 1978 version didn't use the student. any openion?

1 Answers  


how you can say about a slab that it is one way or two way.

6 Answers  


the diff bet face left & face right observation of theodolite is 3' the error is 45'' 1'30'' 3' 0'

1 Answers  


where should the lap of a beam should be

1 Answers  


How to do base isolation for RC framed structure using ETABS software?

0 Answers  


Why the name is "partial safety factor" why not "safety factor"?

0 Answers   Engineers India Limited,


In T beam design, which are the regions selected as rectangular and Flanged ?

1 Answers  


How to calculate bottom width of landing in a staircase

1 Answers   Tata Steel Limited,


What is alternate bid?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)