Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


in what basis wavelength will select for a compound at
initial method development trials

Answers were Sorted based on User's Feedback



in what basis wavelength will select for a compound at initial method development trials..

Answer / ramkrishna thakare

1 ) for any unknown compound firstly solubility check.
2 ) then on the basis of solubility UV - scanning should
be done

3 ) on the basis of UV - scanning Maxima must be
checked.& then on the basis MAXIMA wavelength should be
selected.it may multiwavelength or single-wavelength maxima .


RAMKRISHNA THAKARE -------SANDOZ

Is This Answer Correct ?    29 Yes 1 No

in what basis wavelength will select for a compound at initial method development trials..

Answer / u.venkatramireddy

Based on Chromophore in the compound

posted by uvreddy
DrReddy's

Is This Answer Correct ?    4 Yes 2 No

in what basis wavelength will select for a compound at initial method development trials..

Answer / vijay

Based on wavelength of the compound. Not only lambda max we have to consider co-elute peak, cut off value of solvent.

Is This Answer Correct ?    1 Yes 0 No

in what basis wavelength will select for a compound at initial method development trials..

Answer / shami thakur

Not mentioned type of method development UV or HPLC
During hplc method development mobile phase are selected according to dissociation constant value and all study carried with the help of PDA detector wavelength range 200-400nm

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 Answers   Torrent Pharma,


diference b/w packed &capilary columns

2 Answers  


What is the use of ELSD in HPLC?

3 Answers   Anthem,


Calculate the water content in Di Sodium Tartrate (DST) based on molecular weight?

3 Answers  


what are the different methods of analysing related substances test,what are LOD AND LOQ .HOW TO REPORT IMPURITIES WHEN LOD AND LOQ LIMITS R SPECIFIED

3 Answers   Dr Reddys,


Why are using in Hi,zero air, Ni gass are used GC

5 Answers   Aurobindo, ELBS, Vimta Labs,


why plane of polarized light rotated by opticaly active compunds?

1 Answers   Glenmark,


in which situation ion pair require to use?

0 Answers  


process of Diclofenac sodium,IP.

0 Answers  


ash or residue in that what will be there.

3 Answers  


what is difference of uv and pda

13 Answers   Akums, MSN, MSN Pharma, Shilpa Medicare,


why chiral compounds will rotate the plane polarized light in SoR.

4 Answers   GVK,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)