What is the fuction of surge arrester and surge suppressor?
Modern days line designes are based on which surge?



What is the fuction of surge arrester and surge suppressor? Modern days line designes are based on ..

Answer / iamdon

Surge arrester povides a low resistive path for lightning
and switching surges and thus diverting it through the low
resistive path,hence protect the device.

Surge suppresser reduce the peak and rate of rise of
switching surges.

Modern days line designes are mainly based on switching
surges.

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    5 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

In the diesel generator if there is an AVR (auto voltage regulator) gone faulty, in this condition is there any way to generate the voltage from the alternator? I need a brief explanation can you please help somebody

1 Answers   Vodafone,


if negative of DC supply used and positive is grounded through EGB, and if ELCB used in the system then is it sense the positive volatge and get tripped is it possible?

0 Answers   Delta,


What is the difference between single point and double point bonding. please kindly detail about bonding of cables.

0 Answers  


what is swirl induction in i.c engine????????

1 Answers   Ashok Leyland,


what is meant by dielectric breakdown ? where we using HV test kit & what purpose?

3 Answers   ITC Infotech,






Whats the minimum value for I.R. that can be allowed for HT & LT alternators for operation?

1 Answers  


_____hamari_____tumhari____ne dil ki_____utari. _____ne ____ dekha ashe ___ doshti ko lage na hamari.Complete pajal

1 Answers   Microfine Industries,


how can we test the vector group of transformer

1 Answers  


define ac reactor? thier application;

1 Answers  


define one ampere?

2 Answers  


What are the advantages and disadvantages of oil filled transformers?

2 Answers   Mercantile Marine Department, Studio College,


when we megger is not damaged when we are measuring very low resistance? high d.c. voltage is produced in megger so according to i=V/R. current will be high so what is the reason ?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)